SELECTION OF POWER OIL TRANSFORMERS WITH RANDOM NON-PERIODIC NATURE OF ELECTRIC LOAD

Authors

  • Ivan Vasylovych Prytyskach Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Ukraine https://orcid.org/0000-0002-1892-0054

DOI:

https://doi.org/10.20535/1813-5420.0.2013.149928

Keywords:

power supply system, electrical load, transformer, stochastic model, thermal model

Abstract

Unlike deterministic selection models, which often leads to significant errors, stochastic selection models can use more adequate model of electrical load as a random process that can be both periodic and non-periodic. In this paper presented the method of oil transformers power selection according to the criteria of their heating and acceptable insulation wear from thermal model according MGOST 14209-97 using statistical characteristics of the electric load as a non-periodic random process. This simulation was carried out by modelling oil and most heated point temperature of the transformer and the relative deterioration of its insulation to provide their statistical characteristics primarily determined by the quantile function with corresponding probabilities. Also presented a comparison of this approach with a selection in which the load is considered as stationary random process.

References

МГОСТ 14209-97. Руководство по нагрузке силовых масляных трансформаторов. Дата введения 2002.01.01.

Денисенко М.А. Спеціальні питання електропостачання. – К.: НТУУ «КПІ», 2009. – 288 с.

Праховник А. В. Від управління електроспоживанням до енергетики сталого розвитку // Вісник НТУУ «КПІ». Серія «Гірництво». – 2010. – Вип. 19.

Issue

Section

TECHIQUE